Abstract

The collapse of the I-35W Bridge in Minneapolis, Minnesota has raised questions regarding the performance and possibly safety of steel truss bridges. The failure investigation indicated that the collapse was due to a design error in the gusset plates used to connect the truss members. The findings also recommend that evaluation of truss connections will be needed, which is a deviation from past practice where only members were considered. Gusset plates connect individual steel truss bridge members together at a node. In 10% of the 200,000 steel bridges in US in 2008, failure of a single truss or connection could lead to collapse. Regular inspection and load rating are essential for the safe operation and maintenance of these bridges. The Minneapolis I-35 Bridge collapse was the first gusset failure where a design flaw was implicated. Load rating gusset plates is a significant challenge given the number of connections and the complexity of accurately evaluating each one. The majority of research on gusset plate strength is from small-scale connections. More refined techniques are needed to conduct high-fidelity capacity evaluations. Finite element analysis (FEA) is widely used in structural engineering. Using FEA in gusset plate evaluation presents challenges due to the connections’ large-scale, high degree of geometric variability and complex load paths.

Description

This is a final report, OTREC-RR-12-03, from the NITC program of TREC at Portland State University, and can be found online at: http://nitc.trec.pdx.edu/research/project/361

The project brief associated with this final report can be found at: http://archives.pdx.edu/ds/psu/16932

DOI

10.15760/trec.76

Persistent Identifier

http://archives.pdx.edu/ds/psu/16930

Share

COinS