Sponsor
This work was supported by National Science Foundation Grant ATM-0513492, by the Electric Power Research Institute, and by the Cooley Family Fund for Critical Research of the Oregon Community Foundation.
Published In
Atmospheric Chemistry and Physics
Document Type
Article
Publication Date
5-2008
Subjects
Vapor pressure -- Measurement, Organic compounds, Enthalpy
Abstract
The SIMPOL.1 group contribution method is developed for predicting the liquid vapor pressure poL (atm) and enthalpy of vaporization Δ Hvap (kJ mol-1) of organic compounds as functions of temperature (T). For each compound i, the method assumes log10poL,i (T)=∑kνk,ibk(T) where νk,i is the number of groups of type k, and bk (T) is the contribution to log10poL,i (T) by each group of type k. A zeroeth group is included that uses b0 (T) with ν0,i=1 for all i. A total of 30 structural groups are considered: molecular carbon, alkyl hydroxyl, aromatic hydroxyl, alkyl ether, alkyl ring ether, aromatic ether, aldehyde, ketone, carboxylic acid, ester, nitrate, nitro, alkyl amine (primary, secondary, and tertiary), aromatic amine, amide (primary, secondary, and tertiary), peroxide, hydroperoxide, peroxy acid, C=C, carbonylperoxynitrate, nitro-phenol, nitro-ester, aromatic rings, non-aromatic rings, C=C–C=O in a non-aromatic ring, and carbon on the acid-side of an amide. The T dependence in each of the bk (T) is assumed to follow b(T)=B1/T+B2+B3T+B4ln T. Values of the B coefficients are fit using an initial basis set of 272 compounds for which experimentally based functions po L,i=fi (T) are available. The range of vapor pressure considered spans fourteen orders of magnitude. The ability of the initially fitted B coefficients to predict poL values is examined using a test set of 184 compounds and a T range that is as wide as 273.15 to 393.15 K for some compounds. σFIT is defined as the average over all points of the absolute value of the difference between experimental and predicted values of log10poL,i (T). After consideration of σFIT for the test set, the initial basis set and test set compounds are combined, and the B coefficients re-optimized. For all compounds and temperatures, σFIT=0.34: on average, poL,i (T) values are predicted to within a factor of 2. Because d(log10 poL,i (T))d(1/T) is related to the enthalpy of vaporization ΔHvap,i, the fitted B provide predictions of ΔHvap,i based on structure.
DOI
10.5194/acp-8-2773-2008
Persistent Identifier
http://archives.pdx.edu/ds/psu/8883
Citation Details
Pankow JF, Asher WE (2008) SIMPOL.1: a simple group contribution method for predicting vapor pressures and enthalpies of vaporization of multifunctional organic compounds. Atmos. Chem. Phys., 8, 2773-2796.
Description
Originally published in Atmospheric Chemistry & Physics. Article may be found at http://www.atmospheric-chemistry-and-physics.net/