Abstract

Metal-organic Frameworks (MOFs) are a group of crystalline and highly porous materials consisting of inorganic metal ions/clusters (nodes) that are coordinated by organic linkers. The ability to create a wide range of porous structures, where the pore size can be easily changed in size and shape offers the potential for many applications in gas storage/separation and catalysis. The presence of the organic linkers or “struts” in the sample creates challenges for high resolution microscopy as the sample itself is very sensitive to beam damage. A key challenge for understanding the structures of MOFs and how the applications can be modified by doping the nodes and changing the nature of the organic linkers, is therefore to be able to image the samples on the sub-nm length scale (the nodes are ~1 nm).

The study of organics, where large single crystals with long-range order cannot be synthesized, is usually performed by either electron crystallography or direct imaging in the (scanning) transmission electron microscope (S/TEM). In the (S)TEM, large single crystals are not needed as the electron beam can be focused to a very small area (sub-nm if needed). The downside to this ability to see small areas is that because the electron beam has a strong interaction with the sample, it can cause significant levels of electron beam damage. However, the last 40 years of protein crystallography and more recently the use of in-situ liquid stages to study chemical reactions in the (S)TEM, have shown that this beam damage effect can in most cases be mitigated by the use of extremely low-dose imaging (a dose rate of less than 0.1 electrons/angstrom2/s and a cumulative dose of less than 10 electrons/angstrom2). In addition to simply lowering the dose through conventional means (changing the emission current and probe dwell time), more recent use of compressive sensing/in-painting methods for STEM has also been shown to lower the effective dose and dose rate.

Description

© Microscopy Society of America 2017

This work was authored as part of the Contributor's official duties as an Employee of the United States Government and is therefore a work of the United States Government. In accordance with 17 U.S.C. 105, no copyright protection is available for such works under U.S. Law.

DOI

10.1017/S1431927617009680

Persistent Identifier

https://archives.pdx.edu/ds/psu/26738

Included in

Physics Commons

Share

COinS